Main Documents
Description
PMC-220 Single-Phase Multifunction Meter
Device Introduction
- The PMC-220 Single-Phase Multifunction Meter is CET's latest offer for the low voltage energy metering market featuring DIN-Rail mount, compact construction, 63A direct input and high accuracy measurements.
- The PMC-220 complies with the IEC 62053-21: 2020 Class 0.5 kWh Accuracy Standard. With the standard RS485 port and Modbus RTU protocol, the PMC-220 becomes a vital component of an intelligent, multifunction monitoring solution for any Energy Management Systems
Product Highlight
- Low-Cost Single-Phase Multifunction Meter
- IEC 62053-21:2020 Class 0.5 (63A Direct Input)
- NMI M6-1 Class 1
- 35mm DIN Rail, 36x65x90mm
- 6½ Digit B&W LCD Display
- Modbus RTU,1xRS-485
- 1xSS Pulse Output
Typical Application
- DIN-Rail mount energy metering
- Industrial and commercial metering
- Substation, building and factory automation
- Sub-metering
Related Products
Related Solutions
Specification
Technical Specification
Measurement Inputs(L,N,L',N’)
Voltage (Un)
220VAC | 230VAC | 240VAC
Overrange (% Un)
120% | 115% | 110%
Range (V)
95-264VAC
Current (Ib/Imax)
5A/63A
StartingCurrent (Ist)
0.4% Ib (0.02A)
Minimum Current (Imin)
5% Ib (0.25A)
Frequency
45Hz-65Hz
Power Supply
Self-powered from 95 to 264VAC
Maximum Wire Size
25 mm2 (4AWG)
Torque for L, N Terminals
2.5 N.m
Communications(D+,D-)
RS-485 (Modbus RTU)
Optically isolated @ 5kVrms
Maximum Wire Size
1.5 mm2 (16AWG)
Torque for RS-485 Terminals
0.45 N.m
Torque for RS-485 Terminals
0.45 N.m
Pulse Output(E+,E-)
Type
Optically Isolated Solid State Relay
Max.Load Voltage
80 VDC
Max.Forward Current
50 mA
Maximum Wire Size
1.5 mm2 (16AWG)
Torque for RS-485 Terminals
0.45N.m
Environmental Conditions
Operating Temp.
'-25 °C to + 70°C
Storage Temp.
'-40 °C to + 85°C
Humidity
5% to 95% non-condensing
Atmospheric Pressure
70 kPa to 106 kPa
Pollution Degree
2
Mechanical Characteristics
Unit Dimensions
36x65x90mm
Shipping Weight
0.18kg
Shipping Dimensions
120x103x42mm
Mounting
DIN-Rail Mounting
IP Rating
IP51(Front), IP30(Body)
Communications
Protocol
Modbus RTU
RS-485 Port
1
Features Summary
Display (Backlit)
B&W (No Backlit)
Accuracy
Parameters
Accuracy
Resolution
Voltage
±0.5% reading
0.1V
Current
±0.5% reading
0.001A
kW,kVA
±1.0%
0.001kX
kvar
±1.0%
0.001kvar
kWh
IEC 62053-21:2020 Class 0.5
NMI M6-1 Class1
NMI M6-1 Class1
0.01kWh
kvarh
IIEC 62053-23:2020 Class 2
0.01kvarh
kVAh
IEC 62053-21:2020 Class 0.5
0.01kVAh
PF
±1.0%
0.001
Frequency
±0.02Hz
0.01Hz
Standards of Compliance
Safety Requirements
CE LVD Directive 2014/35/EU
EN 61010-1: 2010 + A1: 2019
EN 61010-2-030: 2010
EN 61010-2-030: 2010
Insulation
AC Voltage
Impulse Voltage
IEC 62052-31: 2015
NMI M6-1
4kV @ 1 minute
12kV+0%, -15%, 1.2/50µs (NMI M6-1)
Electrical Safety in Low Voltage Distribution Systems up to 1000Vac and 1500Vdc
IEC 61557-12:2018(PMD)
Electromagnetic Compatibility
EMC 2014/30/EU(EN 61326:2013)
Electrostatic Discharge
EN 61000-4-2:2009
Radiated Fields
EN 61000-4-3:2006+A1:2008+A2:2010
Fast Transients
EN 61000-4-4:2012
Surges
EN 61000-4-5:2014+A1:2017
Conducted Disturbances
EN 61000-4-6:2014
Magnetic Fields
EN 61000-4-8:2010
Voltage Dips and Interruptions
EN 61000-4-11:2004+A1:2017
VRing Wave
EN 61000-4-12:2017
Mechanical Tests
Spring Hammer Test
IEC 62052-31:2015
Vibration Test
IEC 62052-11:2020
Shock Test
IEC 62052-11:2020
Revenue Metering Approval
NMI M6-1 of Australia
Approval Mark: NMI 14/2/98
UL Ref. # R11353641-CETA-NMI M6-1
- Choosing a selection results in a full page refresh.