PMC-53A-E Ethernet Multifunction Meter

SKU:
$760.00 USD

Sub-Model: PMC-53A-E-5925AAE

PMC-53A-E-5925AAE
PMC-53A-E-5925AAE
PMC-53A-E-5925AXE

Main Documents

Description

PMC-53A-E Ethernet Multifunction Meter


Device Introduction

  • The PMC-53A-E Ethernet Multifunction Meter is CET's latest offer for the digital power/energy metering market. Housed in a standard DIN form factor measuring 96x96x88mm, it is perfectly suited for industrial, commercial and utility applications requiring direct Ethernet connectivity.
  • The PMC-53A-E features quality construction, multifunction measurements and a large, backlit, Dot-Matrix LCD that is easy to navigate and user friendly. Compliance with the IEC 62053-22 Class 0.5S and ANSI C12.20 Class 0.2 Standards, it is a cost-effective replacement for analog instrumentation and is capable of displaying 4 measurements at once. It also optionally provides an I4 input for Neutral Current Measurement, one 0/4-20mA Analog Input for measuring external transducer signal as well as an Ir Input for Residual Current Measurement. With a standard 100BaseT Ethernet Port and a RS-485 port supporting multiple protocols.
  • The PMC-53A E can be easily integrated into Energy Management Systems as well as Building and Utility Automation Systems. The on-board password protected Web Server provides user-friendly access to its data and supports the configuration for most of the Setup parameters via a standard web browser.

Product Highlight

  • IEC62053-22 Class 0.5S
  • DIN96 (92x92mm Cutout)
  • Backlit Dot-Matrix LCD Display
  • Harmonics, Demands & TOU, Energy Log, Max/Min Log and Event Log
  • Waveform Capture on Screen
  • Modbus RTU, TCP, HTTP, SNTP, SMTP, TFTP, BACnet, DNP3.0
  • 1xEthernet, 1xRS-485
  • 4xDI, 2xDO, 1xI4, 1xIr and 1xAI

Typical Application

  • Industrial, Commercial and Utility Substation Metering
  • Building, Factory and Process Automation
  • Sub-metering and Cost Allocation
  • Retrofit applications with optional Class 0.5 Split-Core CTs

Related Products

Related Solutions

Specification

Technical Specification

Voltage Inputs(V1,V2,V3,VN)
Standard Un
400ULN/690ULL
Range
10V to 1.2Un
Overload
1.2xUn continuous, 2xUn for 1 s
Burden
<0.02VA/phase
Measurement Category
CAT III up to 600ULL
Frequency
45-65Hz
Current Inputs(I11,I12,I21,I22,I31,I32)
Standard
5A(Optional 1A)
SCCT Options
100A/200A/400A/800A/1600A to 40mA Output
Range
0.1% to 200%In
Starting Current
0.1%In
Overload
2xIn continuous, 20xIn for 1 s
Measurement Category
CAT III up to 600ULL
Burden
<0.15VA per phase@5A
Power Supply(L+,N-)
Standard
95-250VAC/DC,±10%,47-440Hz
Optional
20-60VDC
Burden
<3W
Overvoltage Category
CAT III up to 300VLN
Digital Inputs(DI1,DI2,DI3,DI4,DIC)
Type
Dry contact,24VDC internally wetted
Sampling
1000Hz
Hysteresis
1ms minimum
Digital Outputs(DO11,DO12,DO21,DO22)
Type
Form A Mechanical Relay
Loading
5A@250VAC or 30VDC
Load Type
Resistive
Optional SS Pulse Outputs(E1+,E1-,E2+,E2-)
Type
Form A Solid State Relay
Isolation
Optical
Load Type
Resistive
Output
Optocoupler output as ON-OFF
Max.Load Voltage
50VDC
Max.Forward Current
50mA
Optional I4 Input(I41,I42)
In
5A (5A/1A Auto-Scaling)
Range
0.1% to 120%In
Starting Current
0.1%In
Optional Residual Current Inputs(·IR,IR)
In
0.5mA
Range
2% to 500%In
CT Type
Solid-Core or Split-Core Residual Current CT
Optional Analog Input(AI+,AI-)
Type
0-20/4-20mA
Overload
24mA maximum
Installation Torque
Current Inputs
12 Ib-in(1.3N.m)
Power Supply,Voltage Inputs,RS-485 and I/O
5 Ib-in(0.5N.m)
Environmental Conditions
Operating Temp.
-25 °C to + 70°C
Storage Temp.
-40 °C to + 85°C
Humidity
5% to 95% non-condensing
Atmospheric Pressure
70 kPa to 106 kPa
Altitude
<2000m
Pollution Degree
2
Location/Mounting
For indoor use only
Mechanical Characteristics
Panel Cutout
92x92mm(3.62”x3.62”)
Unit Dimensions
96x96x88mm
IP Rating
IP65(Front Panel), IP30(Body)
Communications
Protocol
Modbus RTU, Modbus TCP ,BACnet MS/TP, DNP3.0, Ethernet Gateway, SNTP, SMTP, TFTP
RS-485 Port
1
Ethernet
1
Web Server
Features Summary
Display (Backlit)
Dot-Matrix LCD (Backlit)
Type of Measurement
ULN per Phase &Avg.
ULL per Phase&Avg.
Current per Phase &Avg.
Neutral Current (Meas./Calc.)
Frequency
kW per Phase & Total
kvar per Phase & Total
kVA per Phase& Total
PF per Phase& Total
kWh lmport/Export
kvarh Import/Export
kVAh Total
Power Quality
THD Voltage & Current
TOHD Voltage & Current
TEHD Voltage & Current
2nd-31st Harmonics
K-Factor
Voltage/Current Unbalance
Battery-backed Real-time Clock
Demands
Present , Predicted Demands and Max.Demands for This Month & Last Month
Multi-Tariff TOU capability
Two TOU schedules, each providing:
12 Seasons
90 Holidays
20 Daily Profiles, each with 12 Periods in 15-minute interval
8 Tariffs
Diagnostics
Setpoints
9 Setpoints
Logs
Max./Min.Log
This month & Last Month
Freeze Logs(Optional)
60 Daily Freeze Logs, 36 Monthly Freeze Logs
Monthly Energy Log
12 months
Data Recorder
5 Data Recorders
Max. Recording Depth @ 10000 records
SOE Log
100 entries
On-board Log Memory
8MB

Accuracy

Parameters
Accuracy
Resolution
Voltage
±0.2%
0.001V
Current
±0.2%
0.001A
I4(measurement)
±0.2%
0.001A
Ir(measurement)
±0.5%
0.001A
P,Q,S
±0.5%
0.001kx
kWh,kVAh
5A/1A Option:
 IEC 62053-22 Class 0.5S
 ANSI C12.20 Class 0.2
SCCT Option:
 IEC 62053-21 Class 1
0.1kWh
kvarh
5A/1A Option:
 IEC 62053-24 Class 0.5S
 IEC 62053-23 Class 2
SCCT Option:
 IEC 62053-24 Class 1
 IEC 62053-23 Class 2
0.1kvarh
PF
±0.5%
0.001
Frequency
±0.02Hz
0.01Hz
THD
IEC 61000-4-7 Class B
0.001%
K-Factor
IEC 61000-4-7 Class B
0.001
Phase Angle
±1°
0.1°

Standards of Compliance

Safety Requirements
CE LVD 2014/35/EU
EN 61010-1: 2010
EN 61010-2-030: 2010
cULusListed
EN61010-2-030:2010
UL61010-1,Ed.3
CAN/CSAC22.2NO.61010-1-12,Ed.3
UL61010-2-030,Ed.2
CSAC22.2NO.61010-2-030:18,Ed.2
UL61010-2-030,Ed.2
CSAC22.2NO.61010-2-201Ed.2
Electrical Safety in Low Voltage Distribution Systems up to 1000Vac and 1500Vdc
IEC 61557-12:2018(PMD)
Insulation
AC Voltage: 2kV@1 minute
Insulation Resistance: >100MΩ
Impulse Voltage: 6kV,1.2/50µs
IEC 62052-11: 2003
IEC 62053-21: 2003
Electromagnetic Compatibility CE EMC Directive 2014/30/EU(EN 61326:2013)
Immunity Tests
Electrostatic Discharge
EN 61000-4-2:2009
Radiated Fields
EN 61000-4-3:2006+A1:2008+A2:2010
Fast Transients
EN 61000-4-4:2012
Surges
EN 61000-4-5:2014+A1:2017
Conducted Disturbances
EN 61000-4-6:2014
Magnetic Fields
EN 61000-4-8:2010
Voltage Dips and Interruptions
EN 61000-4-11:2004+A1:2017
Ring Waves
EN 61000-4-12:2017
Emission Tests
Limits and Methods of Measurement of Electromagnetic Disturbance Characteristics of Industrial,Scientific and Medical(ISM) Radio-Frequency Equipment
EN 55011:2016
Electromagnetic Compatibility of Multimedia Equipment - Emission Requirements
EN 55032:2015
Limits for Harmonic Current Emissions for Equipment with Rated Current≤16A
EN 61000-3-2:2014
Limitation of Voltage Fluctuations and Flicker in Low-Voltage Supply Systems for Equipment with Rated Current≤16A
EN 61000-3-3:2013
Emission Standard for Industrial Environments
EN 61000-6-4:2007+A1:2011
Mechanical Tests
Spring Hammer Test
IEC 62052-11:2003
Vibration Test
IEC 62052-11:2003
Shock Test
IEC 62052-11:2003
Radiated Emissions
FCC 47CFR 15.109 ClassB
Conducted Emissions
FCC 47CFR 15.107 ClassB

Wiring Mode

Wiring Mode
3P4W
3-Phase 4-Wire (3P4W) Wye Direct Connection with 3CTs or 4CTs
3-Phase 4-Wire (3P4W) Wye with 3PTs and 3CTs or 4CTs
3P3W
3-Phase 3-Wire (3P3W) Direct Delta Connection With 3CTs
3-Phase 3-Wire (3P3W) Direct Delta Connection with 2CTs
3-Phase 3-Wire (3P3W) Delta with 2PTs and 3CTs
3-Phase 3-Wire (3P3W) Delta with 2PTs and 2CTs
1P3W
1-Phase 3-Wire (1P3W) Direct Connection with 2CTs
1P2W L-N
1-Phase 2-Wire, Uln (1P2W-Uln) Direct Connection with 1CT
1P2W L-L
1-Phase 2-Wire, Ull (1P2W-Ull) Direct Connection with 1CT
3×1P
3x1-Phase Direct Connection with 3CTs (Supported in Firmware V1.01.00 or later)